Jean-Paul Biberian: Cold Fusion and the Lattice Energy Converter
Dr. Jean-Paul Biberian has spent more than three decades investigating hydrogen-loaded materials, from ceramic crystals and palladium electrodes to nickel-alloy nanopowders heated above 1,000°C. His latest direction adds a different measurement: electricity from the Lattice Energy Converter. The French physicist suspects these electrical signals and his reported excess heat share a cause. Connecting them could offer a new way to study—and perhaps eventually control—the material behavior that has kept him experimenting long after retirement.
A Research Program Built One Experiment at a Time
Ten grams of powder, ten watts of reported excess heat: for Jean-Paul Biberian, those numbers suggested an obvious next experiment. Increase the quantity of material, build a larger reactor, and see whether the output rises with it. By November 2026, however, the larger apparatus was refusing to cooperate. A result he’d obtained in a smaller quartz system hadn’t carried over to a larger stainless-steel design. “I’m not successful at the moment,” he told the APEC/AltSci audience. He was still spending weeks trying to find out what had changed.
That persistence has carried Biberian through more than three decades of research. A former professor at the University of Marseille, he retired in 2012 and continued experimenting in his own laboratory. His cold-fusion work began in the early 1990s, during a period that included visiting research at Lawrence Berkeley Laboratory. Since then, he’s investigated ceramic electrolytes, electrochemical cells, hydrogen-permeable metal tubes, supported nanoparticles, and electrical generators. “I enjoy doing these experiments,” he said. Retirement gave him the freedom to keep pursuing them, with collaborators contributing materials, specialized analysis, and additional expertise.
The question reaches back to March 23, 1989, when Martin Fleischmann and Stanley Pons announced results they interpreted as nuclear energy production in an electrochemical cell. Biberian knew both researchers and later obtained equipment and samples associated with their work. What impressed him most was their ability to measure small thermal signals. In his November presentation, he repeatedly returned to the precision of their calorimetry. His own research inherited that practical challenge: determining whether the heat leaving an experimental system exceeds the energy entering it, with enough accuracy to make the difference meaningful.
The Lattice Energy Converter, or LEC, adds electrical measurements to that investigation. Biberian and other researchers report that prepared electrodes can develop voltage and supply current through an external circuit. He suspects this behavior is related to the excess heat he’s measured in separate experiments. His November review brought those research paths together: decades of thermal measurements, an expanding range of hydrogen-treated materials, and a device that offers another way to examine their behavior. The question connecting them is whether the electrical and thermal responses arise from the same physical process.
The First Clue Was Inside a Crystal
Biberian’s first approach used lanthanum aluminate, a ceramic containing lanthanum, aluminum, and oxygen. Following a suggestion from Francis Forrat, he investigated whether vacancies in the crystal could accommodate hydrogen or deuterium and whether an applied electric field could move those species through it. Deuterium is the heavier stable isotope of hydrogen, with a neutron accompanying its proton. Biberian’s idea was to use the crystal environment to bring deuterium into configurations that might favor an unusual reaction. The material’s reported color changes during treatment offered a visible indication that its condition was changing.
The early apparatus placed a crystal between two electrodes, with a heater beneath it and instruments monitoring electrical input and temperature. Biberian could evacuate the chamber or introduce hydrogen or deuterium, then compare the response with a calibration curve. The data acquisition was initially a family operation. His children, then 13 and 15, helped record voltage and current while he measured temperature. He recalls that measurements in vacuum and hydrogen followed the calibration behavior, whereas deuterium produced points above it—a temperature increase he interpreted as excess heat.
Later, he built a more elaborate heat-flow calorimeter. Its diagram shows a sample chamber, insulation, a constant-temperature bath, and 34 type-K thermocouples connected in series. The thermocouples produce an electrical signal associated with the temperature difference across the insulating region; calibration relates that signal to heat flow. The November presentation includes excess-heat estimates of roughly two to four-and-a-half watts, inferred by comparison with calibration curves. The apparatus also supplied heat to maintain its operating temperature, so power delivered through the sample and total heater input must be kept distinct.
The contrast between hydrogen and deuterium gave Biberian a reason to continue. His deuterium measurements departed from the calibrated response, while the hydrogen comparisons he presented showed no corresponding excess. The gases also differ in their thermal properties, making their behavior inside the instrument part of the interpretation. For Biberian, the result justified taking the question into other materials and apparatuses. His subsequent experiments would change both the environment in which hydrogen interacted with matter and the route by which the resulting heat reached a measuring instrument.
Following the Heat Through Water and Metal
After his Berkeley work, Biberian collaborated with Georges Lonchampt on electrochemical experiments. One apparatus shown in his review contained a palladium cathode and a platinum electrode inside a Dewar, with heat carried away through a separate cooling-water circuit. The diagram specifies a distilled-water flow of 100 milliliters per minute and thermistors at the inlet and outlet. Measuring the water’s flow and temperature rise allowed the researchers to estimate the rate at which heat left the cell. The coolant was separate from the electrolyte where the electrochemical process occurred.
Biberian reports that thermal output exceeded electrical input in the heavy-water experiment, while the light-water control behaved differently. The measurement linked heat production to a controlled stream of water and the temperature difference across the cooling circuit. A complete energy balance also has to account for gas recombination, evaporation, condensation, and heat escaping through other parts of the apparatus. This was a different way to examine the problem posed by his crystal experiments: heat was now carried out in a flowing liquid, with the water’s measured temperature rise providing the main signal.
Another experiment moved deuterium through a palladium–silver tube. Biberian connected the idea to earlier NASA observations involving palladium purification equipment. His closed tube was approximately 10 centimeters long and two millimeters in diameter, surrounded by a heater and radiation shields inside a water-cooled reactor. The preparation included oxidation in air near 500°C for two hours. The tube contained about 100 milligrams of palladium powder, identified as 99.95% pure with particles measuring 80–180 nanometers, and the experiment used deuterium at approximately nine atmospheres. Material preparation, pressure, and transport through the metal all became operating variables.
Biberian reports more than five watts of excess heat for five and a half days. A signal persisting over that interval offers much more accumulated energy to examine than a brief temperature excursion, although interpreting it still requires a complete account of gas movement, absorption, desorption, and heat transfer. He said the experiment ended because it was consuming expensive deuterium. Images of the tube’s surface afterward showed substantial changes, including pits and cavities. Those images document altered material, while the calorimetry supplies the separate claim of a sustained thermal imbalance.
Nanoparticles Change the Engineering
The transition to nanoparticles shifted attention toward manufacturing the active material. A small mass divided into tiny particles exposes far more surface than the same mass in a solid rod. It also creates extensive interfaces with whatever holds the particles apart. Surface oxides, particle dimensions, neighboring metals, and the supporting matrix can influence how hydrogen enters and leaves. For Biberian, supported nanoparticles offered a way to investigate those variables systematically. They also introduced a demanding requirement: the preparation process had to produce a material whose relevant properties survived heating and repeated use.
Through contacts associated with Renault and Nissan, Biberian became involved in measurements of powders supplied by Nissan. The material contained palladium and nickel associated with a zirconia support, and the work connected with Japanese investigations including those of Akito Takahashi and collaborators. Biberian’s contribution centered on calorimetry. He designed a larger instrument to accommodate the powder samples and characterize their thermal response. The collaboration placed material preparation and heat measurement in different hands, making the link between a powder’s manufacturing history and its measured behavior especially important.
The calorimeter shown in his presentation used an array of 50 thermocouples. Its Nissan result identifies a 73-gram sample and plots a measured curve reaching roughly five watts of reported excess heat near the upper end of the temperature range, around 450–470°C. A second curve rescales the result to 100 grams for comparison, approaching seven watts. That normalization is useful for comparing specific output, but it doesn’t represent a separate 100-gram experiment. The measurement belongs to the original sample and apparatus; whether a larger charge behaves proportionally is a question for another test.
Biberian described the Nissan measurements as unpublished when he discussed them in November. He also reported concerns about changes in the zirconia-containing material under hydrogen at higher temperatures. Those concerns pushed the research toward another support chemistry. The challenge was to preserve the metal particles and their useful interfaces through repeated heating and gas exposure. Moving beyond several hundred degrees would open a wider operating range, including temperatures attractive for industrial heat and electricity generation, but it would also demand more from the powder, its support, and the reactor surrounding it.
Building a Powder That Can Take the Heat
The European CleanHME project provided a collaborative setting for that next stage. Its official record lists an August 2020 start, a January 2025 end, and approximately €5.51 million in European Union funding. The program investigated hydrogen–metal systems through materials work, measurements, and reactor development. Within it, Biberian worked with collaborators including Robert Michel and Christophe Le Roux on nickel-based powders. The project connected his laboratory measurements with a broader effort to develop materials and experimental methods that could be produced, characterized, and compared across participating organizations.
The preparation route began with hydrotalcite-like layered compounds whose composition could be adjusted before heating and reduction. Biberian described nickel–copper formulations at a seven-to-one ratio, pure-nickel variants, and particles supported by alumina. The starting material was green and nonmagnetic. Vacuum treatment changed its appearance, and hydrogen treatment near 900°C produced a black, magnetic powder. These visible changes were signs of the substantial chemical transformation involved in preparing the material. The test material was therefore the product of a processing history, with composition and treatment both potentially affecting the eventual result.
A separate 10-gram preparation, identified in Biberian’s results as “HT Ni/Bi,” produced a reported excess-heat signal exceeding 11 watts near 1,030°C. The measurement was made during a temperature increase under vacuum following the material’s conditioning. It extends the thermal investigation beyond the nickel–copper formulation described earlier and illustrates why the preparation history matters alongside the material’s nominal composition. This was calorimetric excess heat in a heated system. For Biberian, producing the effect at such temperatures made the work particularly interesting for eventual applications that would use high-temperature heat.
Biberian’s next target was a 100-gram charge producing approximately 100 watts of excess heat. His difficulties with the larger stainless-steel apparatus show why that step requires more than additional powder. A deeper bed changes gas access and temperature distribution. Different walls change heat flow and potentially the sample’s chemical environment. Heating can alter particle size, contacts, and exposed surfaces. Until those effects are characterized, the smaller system’s performance doesn’t establish the larger system’s output. At the presentation, 100 watts was an objective, and understanding the failed scale-up was part of the work needed to reach it.
Searching for a Nuclear Fingerprint
The energy measurements leave a question that has followed cold fusion since 1989: what process produces the reported excess? Biberian summarized the difficulty through the field’s “three miracles”—overcoming the repulsion between positively charged nuclei, explaining the absence of expected neutron production, and accounting for energy without the expected gamma emission. Conventional deuterium fusion has identifiable reaction products. Any proposed alternative must explain its products and energy flow, too. Biberian interprets his results in nuclear terms, but his presentation doesn’t establish a nuclear mechanism for the different thermal and electrical systems it describes.
One attempt to find a nuclear fingerprint used a palladium electrode supplied by Pons after experiments at IMRA in France. Biberian described a sample approximately 10 centimeters long and two millimeters in diameter, subsequently examined by secondary ion mass spectrometry at Montpellier. SIMS removes material from a surface while measuring emitted ions, allowing composition to be followed with depth. Biberian reported a localized enhancement of the signal at mass 107 relative to mass 109, which he interpreted as anomalous silver production near the surface. His 2019 paper notes that the instrument couldn’t distinguish silver-107 from palladium-107. That ambiguity limits the isotope identification, alongside questions about molecular-ion interference, contamination, and sample preparation.
A separate experiment followed work by Ubaldo Mastromatteo on palladium films exposed to a low-power laser in hydrogen. Biberian used a red laser of approximately five milliwatts; an exposure intended to last two weeks extended to roughly three months during the lockdown period. In his November presentation, Biberian described an altered region about 150 micrometers across, with local palladium depletion and signals from other elements, including nitrogen, oxygen, iron, and nickel. Biberian wanted isotope measurements but said the intended analysis couldn’t be completed. The elemental findings consequently leave open questions about the substrate, handling, contamination, and movement of material within the apparatus.
Biberian’s published work also records a compositional change that received a more conventional explanation. In a 2024 nanopowder paper, he and his coauthors reported increased copper in nominally pure nickel material. Follow-up isotope analysis found a copper ratio close to natural composition, leading them to regard contamination as the likely cause. The distinction also applies to the biological elemental changes in seeds and bacteria that he briefly discussed during the Q&A. Changes in elemental concentration identify something to investigate; demonstrating a nuclear transformation requires evidence that separates it from contamination, uptake, loss, or redistribution of material.
An Electrical Signal Across a Gap
The LEC entered Biberian’s research through Frank Gordon and Harper Whitehouse, who asked him to investigate their device. Their work drew attention to a prepared metal electrode that could influence electrical conduction in the surrounding gas and, in suitable configurations, produce voltage and current through an external load. Early presentations and subsequent papers gave other experimenters a comparatively compact apparatus to examine. For Biberian, it offered an additional observable in materials already familiar from his thermal experiments: hydrogen-bearing metals and the surfaces through which hydrogen moved.
The developers trace the work to experiments begun in 2013 on high-temperature gas electrolysis. They were attempting to load hydrogen or deuterium into electrodeposited palladium, using americium-241 sources to ionize the gas. They reported electrical conduction far greater than expected from those sources and followed up with additional experiments, including removal of the radioactive material. Their initial observation concerned gas conductivity during an electrically driven process. It led them to investigate whether prepared electrodes could also support spontaneous voltage and current through an external load.
The basic geometry has an active electrode separated from a counter-electrode inside the cell, with external wiring connecting them through instruments or a load. Sustained current requires a path for charge through the internal region as well as the external circuit. The researchers propose that the active material makes the intervening gas conductive, potentially through ionization. Establishing that process would explain how charge crosses the gap. Identifying the source of the energy that supports sustained electrical output is a further question, requiring measurements of the material and its environment.
For Biberian, the attraction was practical. A voltage could be followed continuously as he changed gas pressure, temperature, or material condition. Connecting a load would show how the response changed when the device supplied current. After years spent building calorimeters, he now had another set of measurements with which to investigate a prepared sample. When the APEC discussion turned to experiments that might help more people enter the field, he pointed to the LEC. Its small size and relatively simple construction made it an appealing candidate for hands-on investigation.
What Biberian’s First LEC Actually Produced
The room-temperature configuration Biberian illustrated used a palladium–silver rod two millimeters in diameter and 100 millimeters long inside a stainless-steel tube with a six-millimeter outside diameter. The rod and outer tube formed separated electrodes. Epoxy seals and gas fittings allowed the chamber to be evacuated and refilled, while electrical connections let him examine its response under different loads. It was a compact arrangement in which material preparation, atmosphere, and the electrical behavior of the gap could be investigated without rebuilding an entire calorimeter.
Biberian varied the resistance connected to the device and plotted voltage, current, and power. At high resistance, the instrument draws little current and can register a relatively large voltage. A lower resistance demands more current, causing the voltage to change as the device’s internal behavior becomes important. The useful characterization is the full response across loads. A voltage reading by itself says little about how much energy the system can deliver; a source must maintain both voltage and current at the operating point where its power is being assessed.
Biberian’s high-resistance voltage plot approaches approximately 540 millivolts. His load curves indicate electrical power on the scale of tens of microwatts, although the voltage, current, and power plots don’t fully reconcile and therefore don’t establish a single precise maximum. The electrical output is small, but it gives experimenters a measurable response to follow as they vary the active material and its environment. The scientific interest lies in identifying what produces that response and how reliably it can be controlled.
The response over time could be as informative as its maximum value. A signal that rises after gas admission, decays as a surface changes, or recovers after a load is removed would help identify which parts of the preparation and operating cycle matter. Continuous voltage and current records could then be compared with gas pressure, temperature, and sample history. That’s the LEC’s appeal as an experimental tool: it offers a way to follow the behavior of an active material while the conditions around it are being changed.
Bringing the LEC Into the Furnace
Biberian’s nanopowder work supplied a reason to heat the LEC. He had reported strong temperature dependence in excess-heat experiments, with some of the largest signals appearing at high temperatures. If electrically active behavior could also be measured from those powders, it might help reveal which material states mattered. He therefore extended the electrical approach beyond the room-temperature palladium arrangement. The work became an attempt to compare two kinds of response in hydrogen-treated materials: heat measured through a calorimeter and charge movement measured through an electrical circuit.
The high-temperature apparatus placed a powder container and counter-electrode within a quartz enclosure approximately 25 millimeters across. An external heater supplied the operating temperature, with temperature sensing and gas connections completing the system. Replacing the long room-temperature electrode with a powder arrangement opened a route to testing materials related to the calorimetric program. It also brought several processes into play at once: heating, hydrogen uptake and release, changes at metal surfaces, and electrical transport through the space between the powder and its counter-electrode.
In the November presentation, the first plotted comparisons show voltage magnitude increasing strongly above approximately 550–600°C. Measurements were made both in hydrogen and under vacuum after hydrogen exposure. One of the latter curves approaches a magnitude of about 300 millivolts near 675°C. The distinction between vacuum and hydrogen-free material is essential here: gas can be removed from a chamber while hydrogen remains within the sample or its previous exposure has changed the surface. The response therefore carries information about both the present atmosphere and the history of the material inside it.
Biberian and his coauthors described the approach in their 2026 paper, “High Temperature LEC Experiments,” reporting thermal and electrical tests using the same powder material. That paper describes voltage under hydrogen and no emission in vacuum; the November presentation also includes voltage under vacuum after hydrogen exposure. The available descriptions don’t establish whether those operating conditions were comparable. Their broader significance is the proposed connection between thermal and electrical behavior. Recording both simultaneously in one operating cell would test whether the signals rise and fall together, giving researchers a stronger basis for investigating a common mechanism.
Voltages That Reverse and Signals That Pulse
The later LEC 94 graph adds a more complicated response. Across nine sequences involving hydrogen and vacuum, the voltage changes direction. Two early vacuum curves reach approximately positive 2.5 volts around 820–840°C. Later curves, including both hydrogen and vacuum runs, are negative; the largest negative excursion approaches 3.5 volts in magnitude near 775°C. At still higher temperatures, the signals move back toward zero. The experiment is consequently richer than a simple claim that heating produces progressively more voltage. Its electrical behavior depends strongly on the path taken through the operating conditions.
Voltage polarity identifies which electrode is at the higher electrical potential. Under a specified load, it also helps establish the direction of current. A reversal may reflect changes in electrode surfaces, retained hydrogen, chemical state, temperature differences, or another part of the charge-transport process. The graph alone doesn’t identify which contribution dominates. A repeatable reversal, however, could become a useful diagnostic: researchers could investigate what changes just before it occurs and whether the behavior follows the material when electrodes or temperature gradients are rearranged. Larger voltage excursions would then serve as clues to the mechanism, rather than stand-ins for an unmeasured power output.
Another graph labels an apparent activation energy of approximately 4.3 electronvolts for a temperature-dependent electrical quantity described as power. Such an analysis compresses the response into a measure of how strongly it changes with temperature. It isn’t a measurement of energy released in a nuclear event. Connecting the approximate fitted value to a microscopic process requires knowing how the electrical quantity was obtained, the load conditions, the relevant temperatures, and the uncertainty of the fit. Temperature-dependent emission and conduction mechanisms also need to be evaluated before the slope can be assigned a specific physical meaning.
The oscilloscope added another feature: a DC signal accompanied by short pulses. Biberian showed voltage traces at 200 millivolts per division, with horizontal settings of 40 microseconds per division and, in an enlarged view, 400 nanoseconds per division. Interpreting them as current requires the sensing circuit that converts current into measured voltage; understanding the pulses also requires their charge, energy, and relationship to heater and instrument activity. Biberian offered no settled explanation. “I’m an experimentalist, I’m not a theoretician,” he said. His immediate contribution was the observed behavior and an invitation to investigate its origin.
Where Does the Electrical Energy Come From?
The LEC poses related but distinct questions about charge transport and energy. A prepared electrode may change conduction through the surrounding gas, and an assembled device may deliver electricity to a load. Understanding how charge crosses the gap doesn’t automatically identify the energy source sustaining that output. The device could therefore be useful as a materials probe or an energy converter while its broader interpretation remained under investigation. Its scientific value depends on what researchers can learn from the measurements, even before they establish whether a nuclear process is involved.
At room temperature, possible contributions include residual electrochemical activity, moisture films, corrosion, hydrogen-related reactions, and energy stored during preparation. These possibilities have experimental consequences. Drying, changing humidity, replacing an electrode, or comparing treated and untreated surfaces may alter the output in distinctive ways. A work-function difference between materials can influence electrical behavior, but naming that difference alone doesn’t explain an indefinitely sustained energy supply. An adequate explanation must identify both the path followed by charge and the process that provides the energy delivered to the external circuit.
The heated device adds a thermal energy supply and additional temperature-sensitive processes. Thermoelectric voltages can arise across dissimilar materials at different temperatures. Thermionic emission can release electrons from sufficiently hot surfaces, and the conductivity of insulating parts can change substantially as they heat. These are reasons to characterize the entire apparatus. Measuring both electrodes’ temperatures, changing the direction of a thermal gradient, or repeating a heating cycle with an inactive sample can show how much of the observed response follows known parts of the system.
The central measurement is an energy balance followed over time. A high-temperature cell may convert supplied heat into electricity, while a prepared room-temperature electrode may release stored energy. Establishing an excess requires accounting for the relevant inputs, reservoirs, and losses. Integrating the output over the device’s operating life is more informative than selecting its largest voltage or pulse. The same discipline underlies Biberian’s calorimetry: identify where energy enters and leaves, characterize ordinary behavior, and determine whether a reproducible difference remains beyond the uncertainties.
Replication Is the Engineering Test
Biberian was direct about the difficulty of reproducing his own LEC results. “Sometimes they work, sometimes they don’t work,” he said during the discussion. That admission sits alongside his continued interest in the experiment: a favorable result gives him something to pursue, while an unsuccessful run raises questions about what changed. His own larger thermal reactor had brought him back to that problem. “You have to be very patient,” he said. Developing a repeatable protocol means identifying the details of preparation and operation that separate those outcomes.
Other investigators have reported related effects with different materials. Antonio Di Stefano’s 2024 paper describes iron deposited on a brass electrode, separated from its counter-electrode by a half-millimeter gap and initially tested in air. He reported 307 millivolts open circuit and 2.4 microamperes short circuit—separate conditions—and charged a 100-microfarad capacitor to 309 millivolts, storing about 4.7 microjoules. The output subsequently deteriorated, accompanied by oxidation of the coating. This supplies a concrete energy-transfer test and a material-lifetime problem, while showing that the reported LEC behavior extends beyond Biberian’s palladium arrangement.
Comparing such experiments requires attention to what was actually reproduced. Testing an electrode prepared by another group, independently preparing a new electrode, and building a different configuration are distinct achievements. Each can provide useful evidence, but they answer different questions about transferability. Composition, surface roughness, deposition conditions, loading history, residual electrolyte, humidity, and aging may all matter. A successful demonstration becomes more informative when the report also includes unsuccessful attempts and the conditions under which the signal weakens, reverses, or disappears.
A reference experiment could organize that information around a defined material, documented preparation, specified gas conditions, standard loads, and complete time-series measurements. Comparison samples would establish the behavior of the same apparatus without the active preparation. Independent laboratories could then vary one factor at a time and compare results on common terms. Even a modest, repeatable electrical output would provide a valuable research platform. It would allow improvements in preparation and explanations of the effect to be tested against a stable experimental baseline.
The Next Result That Would Matter
The most direct test of Biberian’s proposed connection would combine calorimetry and electrical measurements on the same sample. Heater input, thermal output, loaded voltage and current, electrode temperatures, gas pressure, and conditioning history would be recorded together. The experiment would need comparison runs and a clear account of electrical energy extracted from the cell. A correlation between heat and electricity wouldn’t by itself identify the mechanism, but it would impose a stronger constraint on explanations than measurements made separately, without simultaneous thermal and electrical records from the same operating cell.
Targeted nuclear diagnostics could add another independent line of evidence. In a deuterium experiment where helium production is proposed, a useful measurement would need to resolve helium from deuterium-related signals and control atmospheric contamination and leaks. Radiation detectors would need a stated energy range, background, sensitivity, and expected signal. A null measurement becomes informative when it places a quantitative limit on a specified process. Selecting diagnostics around particular hypotheses would help establish which explanations remain compatible with the thermal and electrical records.
Practical energy development would face familiar engineering requirements. A thermal reactor needs stable materials, sustained output, and dependable heat removal. An electrical device needs useful power under load, manageable losses, and demonstrated scaling. Both need a complete system energy balance. Biberian’s hundred-watt objective is one step along that path, while the LEC may offer a nearer-term way to investigate prepared materials. His ambition remains broader than a laboratory measurement. “We need something that everybody can enjoy,” he said, describing the energy applications he hopes the research will eventually make possible.
Biberian compared the development of experimental technology to the distance between a Model T and a Ferrari. His advice was to “do simple experiments with low power, but that means high-quality work.” The larger reactor and the electrically active powders are part of that progression, with each apparatus offering another way to examine what hydrogen and metals are doing together. After three decades, he’s still building, measuring, and trying again. The question now is whether the small electrical signal can help explain the heat—and bring the behavior he’s pursued under experimental control.
References
Presentation and Event
- Cold Fusion — A Review — Jean-Paul Biberian, APEC/AltSci presentation, November 21, 2026. Video presentation accompanying the transcript and slide deck used for this article.
- APEC 11/21: LENR & EVOs, Stellar Engines & Interstellar Drives — Tim Ventura, AltSci. Event information and presentation overview for the November 21, 2026 conference.
Jean-Paul Biberian’s LENR Research
- Cold Fusion — Jean-Paul Biberian, Journal of Condensed Matter Nuclear Science, vol. 13, no. 1, pp. 44–55, 2014.
- Excess Heat in Nanoparticles of Nickel Alloys in Hydrogen — Jean-Paul Biberian and collaborators, Journal of Condensed Matter Nuclear Science, vol. 38, no. 1, pp. 186–195, 2024.
- Transmutation of Palladium Induced by Laser Irradiation — Jean-Paul Biberian, Lawrence Forsley, and Pamela Mosier-Boss, Journal of Condensed Matter Nuclear Science, vol. 37, no. 1, pp. 9–22, 2023.
Lattice Energy Converter Research
- High Temperature LEC Experiments — Jean-Paul Biberian, Robert Michel, and Christophe Le Roux, Journal of Condensed Matter Nuclear Science, vol. 41, pp. 19–24, 2026.
- Lattice Energy Converter — F. E. Gordon and H. J. Whitehouse, Journal of Condensed Matter Nuclear Science, vol. 35, no. 1, pp. 30–48, 2022.
- Lattice Energy Converter II: Iron Hydrogen Host Material — F. E. Gordon and H. J. Whitehouse, Journal of Condensed Matter Nuclear Science, vol. 36, no. 1, pp. 1–24, 2022.
- Experimental Observations on the Lattice Energy Converter — Antonio Di Stefano, Journal of Condensed Matter Nuclear Science, vol. 38, no. 1, pp. 42–50, 2024.
- Scaling up the Lattice Energy Converter — F. E. Gordon and H. J. Whitehouse, Journal of Condensed Matter Nuclear Science, vol. 38, no. 1, pp. 225–234, 2024.
- Progress in Understanding and Scaling Up the Lattice Energy Converter (LEC) — F. E. Gordon and H. J. Whitehouse, Journal of Condensed Matter Nuclear Science, vol. 39, pp. 14–35, 2025.
Research Programs and Historical Background
- Results of an Attempt to Measure Increased Rates of the Reaction D-2 + D-2 Yields He-3 + n in a Nonelectrochemical Cold Fusion Experiment — Gustave C. Fralick, Arthur J. Decker, and James W. Blue, NASA Technical Memorandum NASA-TM-102430, December 1, 1989.
- Clean Energy from Hydrogen-Metal Systems — European Commission CORDIS, CleanHME project record, grant agreement 951974. Official project objectives, participating organizations, funding, and dates.
- Scientific Publications — CleanHME — CleanHME’s publication index, including Biberian’s nanopowder research and related studies of hydrogen–metal systems.